Ensim® Pro for Windows 4.0.0 Patch 6 Release notes

Patch information

Supported version

Installation Prerequisites

  1. Ensim Pro for Windows 4.0.0 - patch 1, 2, 3, 4, 5

These release notes provide information about Ensim® Pro for Windows 4.0.0 Patch 6 resolved issues, installation instructions.
Topics include:

Resolved issue

This section lists the resolved issues of Ensim Pro for Windows 4.0.0 Patch 6. The numbers prefixed by the # symbol indicate the Ensim problem report (PR) number.

#49684 - Ensim Pro hostname change

Installation instructions

Installing the patch on server

Complete the following steps on server:

  1. Login to the server as administrator.
  2. Open a command window and run the command iisreset /stop
  3. Stop the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
    Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Shut Down
  4. Open command shell and switch to <install_dir>\pe\ProvEngine directory where <install_dir> refers to the path where Ensim Pro is installed. For example, if Ensim Pro is installed in C:\Program Files\Ensim\WEBppliance, then switch to C:\Program Files\Ensim\WEBppliance\pe\ProvEngine directory.
  5. Backup w3svcCommon.dll at some other place say C:\beforehotfix6\w3svcCommon.dll
  6. Replace w3svcCommon.dll in the current directory with w3svcCommon.dll packaged in this patch.
  7. Switch to <install_dir>\cp\admin\bin\serviceComponents\w3svc directory. Replace w3svcCommon.dll in the current directory with w3svcCommon.dll packaged in this patch.
  8. Start the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
    Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Start
  9. Open a command window and run the command iisreset /start

Rollback instructions

Rollback of the patch on server
  1. Login to the server as administrator.
  2. Open a command window and run the command iisreset /stop
  3. Stop the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
    Navigate to : Computers > My Computer > COM+ Application > EnsimProvision Engine. Right Click > Shut Down
  4. Open command shell and switch to <install_dir>\pe\ProvEngine directory where <install_dir> refers to the path where Ensim Pro is installed. For example, if Ensim Pro is installed in C:\Program Files\Ensim\WEBppliance, then switch to C:\Program Files\Ensim\WEBppliance\pe\ProvEngine directory.
  5. Copy C:\beforehotfix6\w3svcCommon.dll to current directory
  6. Switch to <install_dir>\cp\admin\bin\serviceComponents\w3svc directory. Copy C:\beforehotfix6\w3svcCommon.dll to current directory
  7. Start the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
    Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Start
  8. Open a command window and run the command iisreset /start

Ensim Corporation
1366 Borregas Avenue
Sunnyvale, California 94089
http://dog.ensim.com/processes/Templates/www.ensim.com